Which of the following actions should be taken if during a routine maintenance inspection of a centrifugal pump, localized scoring on a pump shaft sleeve is detected?

  1. ACorrect the cause of the scoring and repair the sleeve or replace with a new one. ✓
  2. BReassemble the unit and provide more water leak off for proper lubrication.
  3. CCheck for parallel alignment of the sleeve radial faces to the sleeve bores.
  4. DReassemble the unit and adjust the governor to obtain a slower speed.

Correct answer: A) Correct the cause of the scoring and repair the sleeve or replace with a new one.

USCG question bank (2008) · Engineering General Subjects – Question Bank Book 11 · pass mark 70%