SeaQuiz

Carbon deposits forming on the discharge valves of an air compressor are caused by oil deterioration under high pressure. The first step in reducing these deposits would be to __________.

  1. Areduce the discharge temperatures with intercoolers ✓
  2. Bincrease the compression ratio
  3. Cuse a high viscosity oil
  4. Dincrease the oil volatility

Correct answer: A) reduce the discharge temperatures with intercoolers

USCG question bank (2008) · Engineering General Subjects – Question Bank Book 11 · pass mark 70%