If an operating bilge pump is developing good vacuum, but is unable to discharge any water, which of the following problems is the most probable cause?
- AThe wearing rings are excessively worn.
- BThe suction strainer is clogged. ✓
- CThe discharge valve is clogged.
- DThe shaft is worn.
Correct answer: B) The suction strainer is clogged.