If the fixed orifice in the evaporator steam supply line were to be removed, the steam pressure reducing valve located upstream would __________.

  1. Abe unable to maintain steam flow unless the proper range spring were to be installed ✓
  2. Bbe suitable for maintaining the required steam flow under all load conditions
  3. Chandle the operation satisfactorily as the control orifice develops an impedance to the steam flow
  4. Dall of the above

Correct answer: A) be unable to maintain steam flow unless the proper range spring were to be installed