A centrifugal pump vibrates excessively during operation. Upon disassembling the pump it is found that the impeller is out of balance. Without an available spare, you should __________.
- Adrill holes through the heavy side of the impeller until it balances
- Bweld counterweights to the light side of the impeller
- Cremove metal from the heavy side by machining in a lathe ✓
- Dacid wash and scrape the heavy side until it balances
Correct answer: C) remove metal from the heavy side by machining in a lathe