If you have a duplex, single acting, reciprocating pump making 140 strokes/minute with a 3" diameter cylinder, and a 12" stroke with a 94% volumetric efficiency, what is the capacity of this pump?
- A28 gpm
- B38 gpm
- C48 gpm ✓
- D58 gpm
Correct answer: C) 48 gpm