If you have a duplex double acting reciprocating pump making 140 strokes/minute, with a 3" diameter cylinder, a 9" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- A72 gpm ✓
- B157 gpm
- C217 gpm
- D285 gpm
Correct answer: A) 72 gpm