If you have a duplex single acting reciprocating pump making 140 strokes/minute, with a 3" diameter cylinder, a 12" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- A193 gpm
- B24 gpm
- C48 gpm ✓
- D97 gpm
Correct answer: C) 48 gpm