What would be the result of throttling the suction valve to the point where the flow was less than that recommended by a centrifugal pump?
I. The designed total net head would be reduced.
II. The pump would begin to cavitate.
- AI only
- BII only ✓
- CBoth I and II
- DNeither I nor II
Correct answer: B) II only