If you have a duplex double acting reciprocating pump making 130 strokes/minute, with a 5" diameter cylinder, a 8" stroke and operating with 93% volumetric efficiency, what is the capacity of this pump?
- A82 gpm
- B164 gpm ✓
- C132 gpm
- D41 gpm
Correct answer: B) 164 gpm