If you have a duplex double acting reciprocating pump making 160 strokes/minute, with a 4" diameter cylinder, a 5" stroke and operating with 95% volumetric efficiency, what is the capacity of this pump?
- A41 gpm
- B52 gpm
- C21 gpm
- D83 gpm ✓
Correct answer: D) 83 gpm