If you have a duplex double acting reciprocating pump making 170 strokes/minute, with a 3" diameter cylinder, a 12" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- A54 gpm
- B217 gpm
- C27 gpm
- D109 gpm ✓
Correct answer: D) 109 gpm