If you have a duplex double acting reciprocating pump making 180 strokes/minute, with a 5" diameter cylinder, a 13" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- A149 gpm
- B388 gpm
- C75 gpm
- D298 gpm ✓
Correct answer: D) 298 gpm