If you have a duplex single acting reciprocating pump making 140 strokes/minute, with a 3" diameter cylinder, a 13" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- A227 gpm
- B52 gpm ✓
- C26 gpm
- D105 gpm
Correct answer: B) 52 gpm