If you have a duplex double acting reciprocating pump making 180 strokes/minute, with a 5" diameter cylinder, a 7" stroke and operating with 98% volumetric efficiency, what is the capacity of this pump?
- A105 gpm
- B210 gpm ✓
- C147 gpm
- D52 gpm
Correct answer: B) 210 gpm