If you have a duplex double acting reciprocating pump making 180 strokes/minute, with a 3" diameter cylinder, a 11" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- A91 gpm ✓
- B45 gpm
- C167 gpm
- D23 gpm
Correct answer: A) 91 gpm