If you have a duplex single acting reciprocating pump making 160 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 85% volumetric efficiency, what is the capacity of this pump?
- A91 gpm
- B26 gpm
- C52 gpm ✓
- D104 gpm
Correct answer: C) 52 gpm