If you have a duplex double acting reciprocating pump making 110 strokes/minute, with a 5" diameter cylinder, a 7" stroke and operating with 79% volumetric efficiency, what is the capacity of this pump?
- A72 gpm
- B26 gpm
- C52 gpm
- D103 gpm ✓
Correct answer: D) 103 gpm