If you have a duplex double acting reciprocating pump making 130 strokes/minute, with a 3" diameter cylinder, a 5" stroke and operating with 91% volumetric efficiency, what is the capacity of this pump?
- A18 gpm
- B30 gpm
- C36 gpm ✓
- D9 gpm
Correct answer: C) 36 gpm