If you have a duplex double acting reciprocating pump making 170 strokes/minute, with a 3" diameter cylinder, a 10" stroke and operating with 77% volumetric efficiency, what is the capacity of this pump?
- A40 gpm
- B80 gpm ✓
- C134 gpm
- D20 gpm
Correct answer: B) 80 gpm