If you have a duplex single acting reciprocating pump making 140 strokes/minute, with a 4" diameter cylinder, a 5" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- A45 gpm
- B36 gpm ✓
- C18 gpm
- D72 gpm
Correct answer: B) 36 gpm