If you have a duplex single acting reciprocating pump making 130 strokes/minute, with a 5" diameter cylinder, a 4" stroke and operating with 96% volumetric efficiency, what is the capacity of this pump?
- A42 gpm ✓
- B34 gpm
- C21 gpm
- D85 gpm
Correct answer: A) 42 gpm