If you have a duplex double acting reciprocating pump making 150 strokes/minute, with a 4" diameter cylinder, a 6" stroke and operating with 95% volumetric efficiency, what is the capacity of this pump?
- A12 gpm
- B25 gpm
- C50 gpm
- D93 gpm ✓
Correct answer: D) 93 gpm