If you have a duplex single acting reciprocating pump making 150 strokes/minute, with a 4" diameter cylinder, a 6" stroke and operating with 95% volumetric efficiency, what is the capacity of this pump?
- A23 gpm
- B34 gpm
- C47 gpm ✓
- D93 gpm
Correct answer: C) 47 gpm