The shaft sleeves have recently been replaced on a centrifugal salt water service pump. The packing gland is now drawn tightly up against the casing. Despite the use of standard procedures to tighten the packing gland, water continues to pour out along the shaft. The probable cause for this situation is that __________.

  1. Athe shaft sleeve "O" ring seals were not installed ✓
  2. Bsuction head pressure has become excessive
  3. Cthe sealing water flow to the stuffing box is blocked
  4. Donly two sections of the lantern ring were installed

Correct answer: A) the shaft sleeve "O" ring seals were not installed

USCG question bank (2008) · Engineering General Subjects – Question Bank Book 11 · pass mark 70%