SeaQuiz

An electric motor driven (torque producing) remotely controlled, valve actuator is installed on the high sea suction with the 'red' indicator light illuminated. When the 'open' push button is depressed, the 'green' indicator light comes on momentarily and then goes out, without any appreciable movement of the valve. Which of the following actions should be carried out?

  1. AAlternately depress the 'close' and 'open' buttons to get the valve open.
  2. BManually engage the actuator handwheel and 'break' the valve disk from its seat, then push the 'open' button. ✓
  3. CSecure power, tag out system and make repairs because the valve stem has sheared.
  4. DSecure the breaker to this device, then switch the motor leads and push the 'open' button.

Correct answer: B) Manually engage the actuator handwheel and 'break' the valve disk from its seat, then push the 'open' button.

USCG question bank (2008) · Engineering General Subjects – Question Bank Book 11 · pass mark 70%