SeaQuiz

What effect does the increased concentration of calcium in boiler water cause?

  1. ALoss of alkalinity, corrosion of metal surfaces, loss of phosphate reserve.
  2. BIncreased alkalinity, inerting of metal surfaces, increase of phosphate reserve. ✓
  3. CDoes not affect alkalinity.
  4. DThe alkalinity increases but the temporary hardness of the boiler water increases.

Correct answer: B) Increased alkalinity, inerting of metal surfaces, increase of phosphate reserve.

← PreviousNext →
Take the full test: F4 Marine Engineering — Operational Level →Random exam test generator, free, no registration