SeaQuiz

During inspection and adjustment, the cam position of the MAN-B&W type MC fuel injection pumps is checked:

  1. AThe stroke of the plunger from its lowest position to the position where the piston of the corresponding cylinder stops at TDC. ✓
  2. BThe stroke of the plunger from its lowest position to the position where the overflow opening is closed.
  3. CThe stroke of the plunger from the position in which the overflow hole is closed to the position in which the piston of the corresponding cylinder stops at TDC.
  4. DA stroke of the plunger from its lowest position.

Correct answer: A) The stroke of the plunger from its lowest position to the position where the piston of the corresponding cylinder stops at TDC.