During inspection and adjustment, the cam position of the MAN-B&W type MC fuel injection pumps is checked:
- AThe stroke of the plunger from its lowest position to the position where the piston of the corresponding cylinder stops at TDC. ✓
- BThe stroke of the plunger from its lowest position to the position where the overflow opening is closed.
- CThe stroke of the plunger from the position in which the overflow hole is closed to the position in which the piston of the corresponding cylinder stops at TDC.
- DA stroke of the plunger from its lowest position.
Correct answer: A) The stroke of the plunger from its lowest position to the position where the piston of the corresponding cylinder stops at TDC.