With worn o-rings on a water-cooled air compressor cylinder liner, where is water most likely to appear when starting the compressor?
- AIn the crankcase where the water mixes with the lubricating oil. ✓
- BIn the low pressure pipeline, when the water is mixed with the air from the compressor.
- CIn the high pressure pipeline, where the water is mixed with the air from the compressor.
- DIn the suction filter for the high pressure cylinders.
Correct answer: A) In the crankcase where the water mixes with the lubricating oil.