In the case of a failure (e.g., fuel supply interruption) of one of the primary movers in parallel-operating generators,the following will happen:

  1. AThe reverse power protection of the faulty diesel generator will activate, preventing it from operating in motor mode. ✓
  2. BThe over-speed protection of the diesel generator will activate.
  3. CThe minimum speed protection of the running diesel generator will activate.
  4. DFuel supply to the problematic diesel generator will be quickly restored.

Correct answer: A) The reverse power protection of the faulty diesel generator will activate, preventing it from operating in motor mode.