A small fire is reported in the forward cargo hold on a vessel equipped with a combination smoke detection/carbon dioxide fixed fire extinguishing system. After ensuring the space is unoccupied and properly sealed off, you should NEXT __________.

  1. Aoperate the control heads mounted on the main pilot cylinders
  2. Bclose all three-way valve levers that are in the detecting position with the exception of the valve(s) to the involved space
  3. Copen the three-way valve whose number (on the handle) corresponds with the line index chart number for the space on fire ✓
  4. Dlock the smoke detector indicator on the monitoring line, which automatically activates the CO2 extinguishing system

Correct answer: C) open the three-way valve whose number (on the handle) corresponds with the line index chart number for the space on fire

USCG question bank (2008) · Engineering Safety – Question Bank Book 15 · pass mark 70%