Steam drum water level indicators must be calibrated to compensate for density differences between the indicated drum water level, and the actual drum water level. If no compensation is made, the indicator will show a __________.

  1. Alower level than exists in the drum with the error becoming greater as the drum pressure decreases
  2. Blower level than exists in the drum with the error becoming greater as the drum pressure increases ✓
  3. Chigher level than exists in the drum with the error becoming greater as the drum pressure decreases
  4. Dhigher level than exists in the drum with the error becoming greater as the drum pressure increases

Correct answer: B) lower level than exists in the drum with the error becoming greater as the drum pressure increases

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%