SeaQuiz

The safety valve hand lifting gear should not be used if the boiler pressure is less than 75% of the safety valve popping pressure in order to __________.
I. provide sufficient steam flow across the valve to prevent the collection of scale on the seat II. prevent cracking of the seat due to chattering of the feather and disc

  1. AI only
  2. BII only ✓
  3. CBoth I and II
  4. DNeither I nor II

Correct answer: B) II only

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%