What will occur if the level of the atmospheric drain tank (fresh water collector) is permitted to continuously decrease while the vessel is underway?

  1. AThe amount of condensate pumped to the contaminated evaporator will decrease.
  2. BThe pressure of the contaminated steam system will drop once the tank is empty.
  3. CMake-up water will be automatically added to the tank via a vacuum drag arrangement.
  4. DThere is a possibility of loosing vacuum in the main condenser. ✓

Correct answer: D) There is a possibility of loosing vacuum in the main condenser.

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%