While standing your engine room watch at sea, you notice the D.C. heater level is dropping below normal as indicated by the remote level indicator. The boiler drum level is observed to be normal, as is the main condensate pump discharge pressure. Therefore, you should __________.

  1. Aincrease the boiler firing rates
  2. Bdecrease the boiler firing rates
  3. Creduce the feed water level set point
  4. Dopen the make-up feed bypass valve ✓

Correct answer: D) open the make-up feed bypass valve

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%