SeaQuiz

If a ship with an automated engine room system develops a 'high' boiler water level at half speed, the __________.

  1. Amain feed water stop valve will automatically close
  2. Bmain feed pump re-circulating line will automatically open
  3. Csurface blow valve will automatically open to lower the level
  4. Dthrottle will be automatically prevented from opening any further ✓

Correct answer: D) throttle will be automatically prevented from opening any further

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%