If a ship with an automated engine room system develops a 'high' boiler water level at half speed, the __________.
- Amain feed water stop valve will automatically close
- Bmain feed pump re-circulating line will automatically open
- Csurface blow valve will automatically open to lower the level
- Dthrottle will be automatically prevented from opening any further ✓
Correct answer: D) throttle will be automatically prevented from opening any further