When raising vacuum on an auxiliary condenser, which of the following steps is necessary?
- AClose the makeup feed drag line to raise hotwell level.
- BOpen the auxiliary condensate recirculation valve from the auxiliary air ejector condenser outlet. ✓
- CRotate turbine with hand jacking gear while applying gland seal steam.
- DClose condensate pump vent line to eliminate air leaks.
Correct answer: B) Open the auxiliary condensate recirculation valve from the auxiliary air ejector condenser outlet.