SeaQuiz

To test an automatic low lube oil pressure trip on an idling turbo generator and at the same time prevent the chance of bearing damage, you should __________.

  1. Aactuate the over speed trip, making a note at what pressure the oil is dumped from under the operating piston
  2. Bclose the generator steam throttle valve and then ensure a supply of oil through the hand or standby pump when the pressure drops to 5-6 psi
  3. Csecure the steam supply valve to the throttle valve and observe the oil pressure as the throttle trips during the slowdown and ensure a supply of oil with the hand or standby pump when the pressure drops to 2-3 psi ✓
  4. Densure the standby lube oil pump, if so equipped, is properly lined up and set in the 'auto' mode, or the hand pump is being operated and then actuate the emergency trip

Correct answer: C) secure the steam supply valve to the throttle valve and observe the oil pressure as the throttle trips during the slowdown and ensure a supply of oil with the hand or standby pump when the pressure drops to 2-3 psi

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%

← PreviousNext →
Take the full practice test: Steam Plants – Question Bank Book 13 →Free USCG practice test with the real pass mark, no sign-up

More questions from this module

Question list: Steam Plants – Question Bank Book 13 (BK13)