SeaQuiz

According to 46 CFR's, steam piping subject to main boiler pressure must be hydrostatically tested at specified intervals. Therefore, which of the following statements is true?

  1. AThe piping must be tested at a pressure and temperature specified by a Coast Guard marine inspector.
  2. BThe piping must be tested at 1 1/2 times working pressure every 4 years.
  3. CPiping under 3 inches nominal pipe size need not be hydrostatically tested. ✓
  4. DThe piping must be tested at 2 times maximum allowable pressure every 4 years.

Correct answer: C) Piping under 3 inches nominal pipe size need not be hydrostatically tested.

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%

← PreviousNext →
Take the full practice test: Steam Plants – Question Bank Book 13 →Free USCG practice test with the real pass mark, no sign-up

More questions from this module

Question list: Steam Plants – Question Bank Book 13 (BK13)