While underway at sea, one of three available centrifugal salt water service pumps is in operation with a sea water temperature of 50°F. The operating temperature of all the systems supplied by this pump appear to be high. Your next proper course of action would be to __________.

  1. Astart a second pump and operate it in parallel
  2. Bstart a second pump and verify a higher discharge pressure after securing the first pump ✓
  3. Cstart the second pump, open the casing vent valve of the first pump, then secure the first pump
  4. Dstart the second pump, secure the first pump and do nothing else with the salt water service system

Correct answer: B) start a second pump and verify a higher discharge pressure after securing the first pump