The boiler water level begins to fall very slowly due to the sudden failure of a water wall tube. In response to this situation, you should continue the feed water supply and immediately __________.
- Areduce the firing rate of the boiler
- Bsecure the forced draft fans
- Csecure the fires and secure the feed water when the level falls out of sight in the gage glass ✓
- Dgag the drum safety valves to prevent loss of steam
Correct answer: C) secure the fires and secure the feed water when the level falls out of sight in the gage glass