SeaQuiz

A steam vessel is operating at sea and despite troubleshooting the system by all the vessel's engineers, the transfer of fuel to the settler has not been possible and the settler will be empty in a few minutes. As the watch engineer, your NEXT step should be to __________.

  1. Aactivate the "engineer needs assistance" alarm
  2. Bline up the diesel cold start system ✓
  3. Cwarm up the emergency generator
  4. Drepeat all the steps that have been taken to determine the cause of the problem

Correct answer: B) line up the diesel cold start system

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%

← PreviousNext →