SeaQuiz

The following information was recorded after a recent L.P. turbine bearing installation. The bearing temperature was logged at the indicated time intervals as:
1200-110°F(43°C)
1210-123°F(51°C)
1220-136°F(58°C)
1230-149°F(65°C)
1240-153°F(67°C)
1250-155°F(68°C) 1300-155°F(68°C) The shaft RPM and lube oil cooler outlet temperature remained constant. The readings indicate __________.

  1. Anormal temperature during wear in ✓
  2. Bwater in the lube oil system
  3. Cwiping of the bearing material
  4. Dexcessive bearing preload conditions

Correct answer: A) normal temperature during wear in