SeaQuiz

Operation of an insulation condition monitoring device involves:

  1. Aa continuous monitoring of resistance of the ship system relative to the hull and activation of alert signalling, ✓
  2. Bmeasuring alternating earth leakage current flowing to the hull and activation of alert signalling,
  3. Ca continuous monitoring of resistance of the ship system in a voltage free state relative to the hull and activation of alert signalling,
  4. Dmeasuring losses occurring with earth leakage current flowing to the hull and activation of alert signalling.

Correct answer: A) a continuous monitoring of resistance of the ship system relative to the hull and activation of alert signalling,